That is correct.

-----Original Message-----
From: seaint-seaosc(--nospam--at)mail-list.com [mailto:seaint-seaosc(--nospam--at)mail-list.com] On 
Behalf Of Joel Adair Sent: Wednesday, November 06, 2013 3:21 PM
To: seaint-seaosc(--nospam--at)mail-list.com
Subject: RE: [SEAINT-SEAOSC] 2013 Codes

I do next to zero wood design, so I can't speak to that, but in the ASD 
load combinations, there's a 0.6 factor on wind loads, to "unfactor" them. 
The code is now treating wind in the same way it treats seismic -- 
generating the loads at the factored level, rather than the service level.

-- Joel