Free Standing Walls

[Subject Prev][Subject Next][Thread Prev][Thread Next]
I am designing some free standing concrete screen walls and it appears that 
 the conventional way to do so is using an R=2.0 per ASCE Table 15.4-2 for 
"Inverted Pendulum Type Structures". With an Sds of 1.56, this gives me an 
ASD sesimic force of about 0.56 x the wall weight. I guess I am still use 
to the old UBC where a ground supported wall in Seismic Zone 4 was 0.2 x 
the wall weight.

So, am I correct in using the 0.56 value, or is there somewherre else in 
the code that could reduce this??

Thanks in Advance,

Larry Hauer, S.E.

-------------------------------------------------------------------------