In the shear wall tables of the 2009 IBC they specifically list common nails and give the required minimum diameter and length.

On 4/5/2015 7:47 AM, Thor Tandy wrote:
I was asked recently if ring shank nails are usable in shear wall design.
They have a smaller shank thank smooth but the thread is said to provide
better withdrawal capacity .?

Any comment?  If they are usable what equivalent shank diameter would one
use to compare the performance?

Thanks

Thor A. Tandy P.Eng, C.Eng, Struct.Eng, MIStructE, FEC
Victoria, BC

Canada
Email:  <mailto:vicpeng(--nospam--at)telus.net> vicpeng(--nospam--at)telus.net

hst_ngc4414_9925Please consider the environment before printing out this
e-mail

--
*
Drew Morris, PE*| Project Engineer
BBFM Engineers, Inc. <http://www.bbfm.com/>